Troubleshooting and fault elimination

System error messages

General error messages

9

9.3

9.3.1

l

9.3−3

EDSVS9332K EN 8.0−07/2013

Remedy

Cause

Description

Fault message

Remedy

Cause

Description

Display

No.

x065

CE4

BUS−OFF state of system bus
(CAN)

The controller has received too
many faulty telegrams via the
system bus (CAN) and has
disconnected from the bus.

l

Check wiring at X4: Is the bus
correctly terminated?

l

Check shield connection of the
cables.

l

Check PE connection.

l

Check bus load, reduce the
baud rate if necessary.
(Observe the cable length!)

l

Switch off the monitoring
(C0595 = 3).

0071

CCr

System failure

Strong interference injection on
the control cables

Screen control cables

Ground or earth loops in the
wiring

l

Check wiring

l

Check PE connection

After troubleshooting: Deenergise
the device completely (disconnect
24 V supply, discharge DC bus)!

0072

PR1

Checksum error in parameter
set 1
CAUTION: The Lenze setting is
loaded automatically!

l

Fault when loading a
parameter set.

l

Interruption while
transmitting the parameter set
via keypad.

l

Set the required parameters
and store them under C0003 =
1.

l

As to PLC devices, check the
use of pointers.

The stored parameters are
incompatible with the loaded
software version.

Store the parameter set under
C0003 = 1 first to allow for a
faults reset.

0074

PEr

Program error

Error in the program flow

Send the parameter set (on floppy
disk/CD−ROM) with a detailed
description of the problem to
Lenze.
After troubleshooting: Deenergise
the device completely (disconnect
24 V supply, discharge DC bus)!

0075

PR0

Error in parameter set.

The operating system software
has been updated.

Storage of the Lenze setting
C0003 = 1.

After troubleshooting: Deenergise
the device completely (disconnect
24 V supply, discharge DC bus)!

0079

PI

Fault during parameter
initialisation

l

An error has been detected
during the parameter set
transfer between two devices.

l

The parameter set does not
match the controller, e.g. if
data has been transferred from
a higher−power controller to a
lower−power controller.

l

Correct parameter set.

l

Send parameter set (on floppy
disk/CD−ROM) and a detailed
description of the problem to
Lenze.

x082

Sd2

Resolver error at X7

Resolver cable interrupted.

l

Check cable for open circuit.

l

Check resolver.

l

Switch off the monitoring
(C0586 = 3).

x083

Sd3

Encoder error at X9

Cable interrupted.

Check cable for open circuit.

Pin X9/8 not connected.

Apply 5 V to pin X9/8 or switch off
monitoring (C0587 = 3).

x085

Sd5

Encoder error at X6/1 and X6/2
(C0034 = 1)

Current signal at X6/1 X6/2 <
2mA.

l

Check cable for open circuit.

l

Check current signal encoder.

l

Switch off monitoring
(C0598 = 3).

x086

Sd6

Motor temperature sensor error
(X7 or X8)

Encoder for detecting the motor
temperature at X7 or X8 indicates
undefined values.

l

Check cable for firm
connection.

l

Switch off the monitoring
(C0594 = 3).