Configuration – Lenze EVS9332xK User Manual

Page 308

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−34

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0781

s

N−INV

10251 R/L/Q−R/L

® Selection list 2 NSET

Configuration of input signal for main
setpoint inversion

C0782

s

NADD

5650 ASW1−OUT

® Selection list 1 NSET

Configuration of input signal for additional
setpoint

C0783

s

NADD−INV

1000 FIXED0

® Selection list 2 NSET

Configuration of additional setpoint
inversion

C0784

s

CINH−VAL

5001 MCTRL−NACT

® Selection list 1 NSET

Configuration of output signal with the
controller being inhibited

C0785

s

SET

5000 MCTRL−NSET2

® Selection list 1 NSET

Configuration of input signal for ramp
function generator

C0786

s

LOAD

5001 MCTRL−QSP−OUT

® Selection list 2 NSET

Configuration of digital input signal for
loading the ramp function generator

C0787

s

® Selection list 2 NSET

Configuration of JOG selection and JOG
activation
Binary interpretation

1 JOG*1

53

DIGIN3

2 JOG*2

1000 FIXED0

3 JOG*4

1000 FIXED0

4 JOG*8

1000 FIXED0

C0788

s

® Selection list 2 NSET

Configuration of Ti selection and Ti activation

l

Binary interpretation

l

T

ir

and T

if

pairs are identical

1 TI*1

1000 FIXED0

2 TI*2

1000 FIXED0

3 TI*4

1000 FIXED0

4 TI*8

1000 FIXED0

C0789

s

RFG−0

1000 FIXED0

® Selection list 2 NSET

Configuration of digital input signal (ramp
function generator 0)

C0790

s

RFG−STOP

1000 FIXED0

® Selection list 2 NSET

Configuration of digital input signal (ramp
function generator stop)

C0798

g −199.99

{0.01 %}

199.99 NSET

Display of analog input signals

1 CINH−VAL

2 SET