Configuration, Code table – Lenze EVS9332xK User Manual

Page 302

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−28

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0644

s

à Selection list 4 PT1−2

Configuration of input signal

1 PT1−2−DFIN

1000 FIXEDPHI−0

C0645 (C0644)

g

PT1−2
Display of input signal

C0646

0

{1 rpm}

16000 PT1−2

1

5

Compensation of the phase shift
(compensation speed) when filter is on
If C0646/1 = 0 is set, the position will be lost

2

15000

Compensation of the phase shift
(compensation speed) when filter is off
If C0646/2 = 0 is set, the position will be lost

C0647

s

à Selection list 2 PT1−2

Configuration of digital input signals

1 PT1−2−DISABLE

FILTER

1000 FIXED0

LOW = filter on
HIGH = filter off

2 PT1−2−RESET

1000 FIXED0

HIGH = filter reset

C0648

g

PT1−2
Display of digital input signals

1 (C0647/1)

2 (C0647/2)

C0650 DT1−1 GAIN

1.000 −320.00

{0.001}

320.00 DT1−1

Gain

C0651 DELAY T

1.00

0.003

{0.01 s}

5.000 DT1−1

Time constant

C0652

s

IN

1000 FIXED0%

® Selection list 1 DT1−1

Configuration of analog input signal

C0653 SENSIBILITY

1

1
2
3
4
5
6
7

15−bit
14−bit
13−bit
12−bit
11−bit
10−bit
9−bit

DT1−1
Sensitivity

C0654 (C0652)

g −199.99

{0.01 %}

199.99

C0655 NUMERATOR

1

−32767

{1}

32767 CONV5

Numerator

C0656 DENOMINATO

R

1

1

{1}

32767 CONV5

Denominator

C0657

s

IN

1000 FIXED0%

® Selection list 1 CONV5

Configuration of analog input signal

C0658 (C0657)

g −199.99

{0.01 %}

199.99 CONV5

Display of analog input signal

C0661

s

IN

1000 FIXED0%

® Selection list 1 ABS1

Configuration of analog input signal
Input for absolute value generator

C0662 (C0661)

g −199.99

{0.01 %}

199.99 ABS1

Display of analog input signal

C0671 RFG1 TIR

0.000 0.000

{0.01 s}

999.900 RFG1

Acceleration time Tir

C0672 RFG1 TIF

0.000 0.000

{0.01 s}

999.900 RFG1

Deceleration time Tif

C0673

s

IN

1000 FIXED0%

® Selection list 1 RFG1

Configuration of analog input signal

C0674

s

SET

1000 FIXED0%

® Selection list 1 RFG1

Configuration of analog input signal