Appendix – Lenze EVS9332xK User Manual

Page 448

Advertising
background image

Appendix

Code−oriented transfer mode

13

13.1

l

13.1−2

EDSVS9332K EN 8.0−07/2013

ƒ Profile data can be accessed via codes. Access via GDC is not possible.

Code

Selection

Meaning

Important

C0389

0: CAM−DATA−offline
(Lenze setting)

Profile data

Mode can only be changed
1. if the controller is inhibited,
2. if profile has been transferred with absolute data model,
3. if the profile data has been accepted in the main memory.

1: CAM−DATA−online

C0392/1
C0392/2
...
C0392/128

0 ... +2147483647

X coordinates
1st part

The coordinate is accessed via the subcode.
Example: C0392/1 = X1, C0392/2 = X2, ... of profile 0 (entries for
C0390/0 = 2)
The values must be entered in ascending order, otherwise NAK.

C0393/1
C0393/2
...
C0393/128

0 ... +2147483647

X coordinates
2nd part

The coordinate is accessed via the subcode.
Example: C0393/1 = X129, C0393/2 = X130, C393/3 = X131, ... of
profile 0 (entries for C0390/0 = 2)
The values must be entered in ascending order, otherwise NAK.

C0394/1
C0394/2
...
C0394/128

0 ... +2147483647

X coordinates
3rd part

The coordinate is accessed via the subcode.
Example: C0394/1 = X1, C0394/2 = X2, ... of profile 1 (entries for
C0390/0 = 2)
The values must be entered in ascending order, otherwise NAK.

C0395/1
C0395/2
...
C0395/128

0 ... +2147483647

X coordinates
4th part

The coordinate is accessed via the subcode.
Example: C0395/1 = X129, C0395/2 = X130, ... of profile 1 (entries
for C0390/0 = 2)
The values must be entered in ascending order, otherwise NAK.

C0396/1
C0396/2
...
C0396/128

±2147483647

Y coordinates
1st part

The coordinate is accessed via the subcode.
Example: C0396/1 = Y1, C0364/2 = Y2, ... of profile 0 (entries for
C0390/0 = 2)

C0397/1
C0397/2
...
C0397/128

±2147483647

Y coordinates
2nd part

The coordinate is accessed via the subcode.
Example: C0397/1 = Y129, C0397/2 = Y130, ... of profile 0 (entries
for C0390/0 = 2)

C0398/1
C0398/1
...
C0398/128

±2147483647

Y coordinates
3rd part

The coordinate is accessed via the subcode.
Example: C0398/1 = Y1, C0398/2 = Y2, ... of profile 1 (entries for
C0390/0 = 2)

C0399/1
C0399/1
...
C0399/128

±2147483647

Y coordinates
4th part

The coordinate is accessed via the subcode.
Example: C0399/1 = Y129, C0399/2 = Y130, ... of profile 1 (entries
for C0390/0 = 2)

Access to profile data