Commissioning

Changing the assignment of the control terminals X5 and X6

Free configuration of digital input signals

6

6.9

6.9.1

l

6.9−1

EDSVS9332K EN 8.0−07/2013

6.9

Changing the assignment of the control terminals X5 and X6

}

Danger!

If you select a configuration in C0005, the signal assignment of
the inputs and outputs will be overwritten with the
corresponding basic assignment!

ƒ

Adapt the signal assignment to your wiring!

6.9.1

Free configuration of digital input signals

ƒ Internal digital signals can be freely linked with external digital signal

sources. This serves to establish a freely configurable control of the
drive controller.
– Digital inputs X5/E1 ... X5/E5

ƒ A signal source can be linked with several targets. Ensure reasonable

linkages for not activating functions that are mutually exclusive (e. g.
linking a digital input with quick stop and DC injection braking at the
same time).

The internal digital signal can be linked with an external signal source by
entering the selection figure of the external signal into the configuration
code of the internal digital signal.

Example

ƒ C0787/2 =53

ð signal source for JOG2 is terminal X5/E3

E1

E2

E3

E4

E5

1

0

C0114/1...6

DIGIN

DIGIN1
DIGIN2

DIGIN3

DIGIN4
DIGIN5

28

DCTRL -X5/28

X5

DIGIN-CINH

1

1

ST

DIGIN6

C0443

NSET

C0046

NSET-N

DMUX

0

3

0

15

NSET-JOG*1
NSET-JOG *2
NSET-JOG *4
NSET-JOG *8

JOG1...15

C0780

C0787/1

C0787/2
C0787/3
C0787/4

9300vec105

Fig. 6.9−1

Connecting digital signal JOG2 with terminal X5/E3

I

Tip!

ƒ

A list with all selection figures is included in the chapter
"Configuration"

® "Selection lists".

ƒ

For signal linkage we recommend the function block editor in
GDC (ESP−GDC2).

Description

Linking signals