Commissioning – Lenze EVS9332xK User Manual

Page 192

Advertising
background image

Commissioning

Basic settings
Motor temperature monitoring with KTY

6

6.5
6.5.7

l

6.5−20

EDSVS9332K EN 8.0−07/2013

The temperature and resistance range can be adapted to the KTY used.

ƒ C1190 = 0: Fixed operating range for KTY in Lenze motors (Lenze

setting)

ƒ C1190 = 1: Adjustable operating range

T [ ° C ]

R [ O h m ]

R 2

( C 1 1 9 2 / 2 )

T 1

( C 1 1 9 1 / 1 )

R 1

( C 1 1 9 2 / 1 )

T 2

( C 1 1 9 1 / 2 )

a

Fig. 6.5−11

Setting of the operating range for the KTY (C1190 = 1)

The operating range is specified by means of limit values and is in the almost
linear section of the graph (a). The operating values are determined by
interpolation.
C1191/1
C1191/2

Setting of the lower and upper temperature value (T1, T2)
corresponding to the KTY used.

C1192/1
C1192/2

Setting of the lower and upper resistance value corresponding to
the KTY used.

Adjustment of KTY operating
range

Advertising
This manual is related to the following products: