Technical data, Wiring of the standard device, Control terminals technical data – Lenze EVS9332xK User Manual

Page 150: 7 technical data

Advertising
background image

Wiring of the standard device

Control terminals
Technical data

5

5.8
5.8.7

l

5.8−10

EDSVS9332K EN 8.0−07/2013

5.8.7

Technical data

Safety relay K

SR

Terminal

Description

Field

Values

X11/K32
X11/K31
X11/33
X11/34

Safety relay K

SR

1st disconnecting path

Coil voltage at +20 °C

DC 24 V (20 ... 30 V)

Coil resistance at +20 °C

823

W ±10 %

Rated coil power

Approx. 700 mW

Max. switching voltage

AC 250 V, DC 250 V (0.45 A)

Max. AC switching capacity

1500 VA

Max. switching current (ohmic load)

AC 6 A (250 V), DC 6 A (50 V)

Recommended minimum load

> 50 mW

Max. switching rate

6 switchings per minute

Mechanical service life

10

7

switching cycles

Electrical service life

at 250 V AC
(ohmic load)

10

5

switching cycles at 6 A

10

6

switching cycles at 1 A

10

7

switching cycles at 0.25 A

at 24 V DC
(ohmic load)

6 × 10

3

switching cycles at 6 A

10

6

switching cycles at 3 A

1.5 × 10

6

switching cycles at 1 A

10

7

switching cycles at 0.1 A

Digital inputs, digital outputs

Terminal

Description

Field

Values

X5/28

Controller inhibit
(DCTRL−CINH)
2nd disconnecting path

PLC level, HTL

LOW: 0 ... +3 V
HIGH: +12 ... +30 V

X5/E1
X5/E2
X5/E3
X5/E4
X5/E5

Digital inputs

PLC level, HTL

LOW: 0 ... +3 V
HIGH: +12 ... +30 V

Input current per input

8 mA for +24 V

Cycle time

1 ms

X5/A1
X5/A2
X5/A3
X5/A4

Digital outputs

PLC level, HTL

LOW: 0 ... +3 V
HIGH: +12 ... +30 V

Load capacity per output

Maximally 50 mA

Load resistance

For +24 V at least 480

W

Cycle time

1 ms

X5/39

GND2

Reference potential for digital signals
Isolated to X6/7 (GND1)

X5/59

Connection of external
voltage source for backup
operation of the drive
controller in the case of
mains failure

Input voltage

DC 24 V (+18 ... +30 V)

Current consumption

Maximally 1 A for 24 V

X5/ST1
X5/ST2

STATE−BUS

Maximum number of nodes

20

Maximum length of the bus cable

5 m

Advertising