Code table

8

8.4

l

8.4−72

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C1461

−16000.0000

{0.0001

rpm}

16000.0000 VMAS1

1

300.0

000

CW speed

2

300.0

000

CCW speed

C1462

0.010

{0.001 s}

999.990 VMAS1

1

1.000

Acceleration time

2

1.000

Deceleration time

C1463

0

{1 rpm}

16000 VMAS1

1

100

Ramp function generator window

2

100

Ramp function generator hysteresis

C1466

s

® Selection list 1 VMAS1

Configuration of analog input signals

1 VMAS1−AIN

1000 FIXED0%

Analog setpoint

2 VMAS1−RED−V

AL

1000 FIXED0%

Alternative analog setpoint, target for speed
reduction

C1467

g

VMAS1
Display of analog input signals

1 (C1466/1)

2 (C1466/2)

C1468

s

® Selection list 2 VMAS1

Configuration of digital input signals

1 VMAS1−EN−AIN

1000 FIXED0

HIGH = Activates the analog inputs
VMAS1−AIN or VMAS1−DFIN (depending on
the selection under C1460)

2 VMAS1−EN−RE

D

1000 FIXED0

HIGH = Activates the analog input
VMAS1−RED−VAL

3 VMAS1−EN−RFG 1000 FIXED0

HIGH = Activates the ramp function
generator
LOW = Input values are processed directly

4 VMAS1−CW

1000 FIXED0

Input of CW rotation (activate speed under
C1461/1)

5 VMAS1−CCW

1000 FIXED0

Input of CCW rotation (activate speed under
C1461/2)

6 VMAS1−RFG=0

1000 FIXED0

HIGH: Set VMAS1−OUT to 0 rpm via the
adjustable ramp in C1463/3. The function has
priority over all other functions.

C1469

g

VMAS1
Display of digital input signals

1 (C1468/1)

... ...

6 (C1468/6)

C1472

s

VMAS1−DFIN

1000 FIXEDPHI−0

® Selection list 4 VMAS1

Configuration of input signal for master
speed (digital frequency)

C1473 (C1472)

g

VMAS1
Display of input signal

C1476

−214000.0000

{0.0001

m−units}

214000.0000 FCODE master

Freely configurable code for master values
[m−units]

1

0.000

0

...

0.000

0

16

0.000

0