Commissioning

Transfer of motion profiles
Transfer of profile data from the controller to the PLC/IPC

6

6.11
6.11.5

l

6.11−10

EDSVS9332K EN 8.0−07/2013

Profile data set (example)

Line

Data

Meaning

1

100

Version identifier

2

4293787648

Profile data

3

4293853166

Profile data

...

...

Profile data

1234

4294641604

Profile data

...

...

Profile data

1242

0

Profile data

1243

55932

Checksum

)

Note!

ƒ

C0505 can only be transferred by a control (PLC or Lenze Drive
PLC). C0505 cannot be addressed via GDC.

ƒ

Every line must be read.

ƒ

Each line may only be read once because the pointer in the
controller automatically jumps to the next element of the
profile data table after a transfer.

ƒ

Repeat the entire transmission process if an error occurs
during the transmission.

Extract from the table of attributes

Code

Index

DS

DA

DT

Format

DL

LCM−

R/W

Condition

dec

hex

C0387

24188 5E7Ch

E

1

FIX32

VD

4

RA/W special

C0504/x

24071 5E07h

A

2

U32

VH

4

RA/W special

C0505/x

24070 5E06h

A

2

B32

VH

4

RA/W special

C0506/x

24069 5E05h

A

2

FIX32

VD

4

RA

C0509

24066 5E02h

E

1

B32

VH

4

RA/W