Safety instructions

General safety information

2

2.1

l

2.1−2

EDSVS9332K EN 8.0−07/2013

ƒ Install the product according to the regulations of the corresponding

documentation. In particular observe the section "Operating
conditions" in the chapter "Technical data".

ƒ Provide for a careful handling and avoid mechanical overload. During

handling neither bend components, nor change the insulation
distances.

ƒ The product contains electrostatic sensitive devices which can easily be

damaged by short circuit or static discharge (ESD). Thus, electronic
components and contacts must not be touched unless ESD measures
are taken beforehand.

ƒ Carry out the electrical installation according to the relevant

regulations (e. g. cable cross−sections, fusing, connection to the PE
conductor). Additional notes are included in the documentation.

ƒ When working on live products, observe the applicable national

regulations for the prevention of accidents (e.g. BGV 3).

ƒ The documentation contains information about EMC−compliant

installation (shielding, earthing, arrangement of filters and laying
cables). The system or machine manufacturer is responsible for
compliance with the limit values required by EMC legislation.
Warning: The controllers are products which can be used in category C2
drive systems as per EN 61800−3. These products may cause radio
interference in residential areas. If this happens, the operator may need
to take appropriate action.

ƒ For compliance with the limit values for radio interference emission at

the site of installation, the components − if specified in the technical
data − have to be mounted in housings (e. g. control cabinets). The
housings have to enable an EMC−compliant installation. In particular
observe that for example control cabinet doors preferably have a
circumferential metallic connection to the housing. Reduce openings or
cutouts through the housing to a minimum.

ƒ Only plug in or remove pluggable terminals in the deenergised state!

ƒ If required, you have to equip the system with additional monitoring

and protective devices in accordance with the respective valid safety
regulations (e. g. law on technical equipment, regulations for the
prevention of accidents).

ƒ Before commissioning remove transport locking devices and keep them

for later transports.

ƒ Keep all protective covers and doors closed during operation.

ƒ Without a higher−level safety system, the described product must

neither be used for the protection of machines nor persons.

ƒ Certain controller versions support safety functions (e.g. "Safe torque

off", formerly "Safe standstill").
The notes on the safety functions provided in the documentation of the
versions must be observed.