Configuration – Lenze EVS9332xK User Manual

Page 309

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−35

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0799

g

NSET
Display of digital input signals

1 (781)

2 (783)

3 (786)

4 (787/1)

5 (787/2)

6 (787/3)

7 (787/4)

8 (788/1)

9 (788/2)

10 (788/3)

11 (788/4)

12 (789)

13 (790)

C0800

s

SET

1000 FIXED0%

® Selection list 1 PCTRL1

Configuration of setpoint input signal

C0801

s

ACT

1000 FIXED0%

® Selection list 1 PCTRL1

Configuration of actual value input signal

C0802

s

INFLU

1000 FIXED0%

® Selection list 1 PCTRL1

Configuration of evaluation input signal

C0803

s

ADAPT

1000 FIXED0%

® Selection list 1 PCTRL1

Configuration of adaptation input signal

C0804

s

INACT

1000 FIXED0

® Selection list 2 PCTRL1

Configuration of inactivation input signal

C0805

s

I−OFF

1000 FIXED0

® Selection list 2 PCTRL1

Configuration of digital input signal (switch
off I−component)

C0808

g −199.99

{0.01 %}

199.99 PCTRL1

Display of analog input signals

1 (C0800)

2 (C0801)

3 (C0802)

4 (C0803)

C0809

g

PCTRL1
Display of digital input signals

1 (C0804)

2 (C0805)

C0810

s

® Selection list 1 ASW1

Configuration of analog input signals

1 IN

55

AIN2−OUT

2 IN

1000 FIXED0%

C0811

s

SET

1000 FIXED0

® Selection list 2 ASW1

Configuration of digital input signal

C0812

g −199.99

{0.01 %}

199.99 ASW1

Display of analog input signals

1 (C0810/1)

2 (C0810/2)

C0813 (C0811)

g

ASW1
Display of digital input signal

C0815

s

® Selection list 1 ASW2

Configuration of analog input signals

1 IN

1000 FIXED0%

2 IN

1000 FIXED0%

Advertising