Configuration – Lenze EVS9332xK User Manual

Page 332

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−58

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C1303

1

{1}

65535 Gearbox factor

1

1

Gearbox factor numerator − master value

2

1

Gearbox factor denominator − master value

C1304

360.0

000

0.0001

{0.0001

units/re

v.}

214000.0000 Output−side feed constant − master value

Output−side feed constant − master value

C1305

1

{1}

65535 Gearbox factor

1

1

Gearbox factor numerator − actual value

2

1

Gearbox factor denominator − actual value

C1306

360.0

000

0.0001

{0.0001

units/re

v.}

214000.0000 Output−side feed constant − actual value

Output−side feed constant − actual value

C1307

0

CDATA
Mode of profile change−over for input
CDATA−RESET

0

Init CAM via LH edge at RESET

A LOW/HIGH edge at CDATA−RESET is used to
change between profiles.

1

Init CAM via HIGH edge at RESET

The level at CDATA−RESET is evaluated.
Changing between profiles is possible when
the level is HIGH.

C1308 WELD MODE

0

WELD1
If FB WELD1 is used, C1308 must be set to 1.

0

Without WELD function

When selecting a configuration without FB
WELD1, C1308 is automatically set to 0.

1

With WELD function

When selecting a configuration with FB
WELD1, C1308 is automatically set to 1.

C1309

100

1

{1 inc.}

18

×10

8

CDATA
Window for zero crossing of the master value

C1310

0

0

{1}

7 CURVEC1

Profile selection

C1311

0

0
1
2
3
4
5
6
7

Profile 1
Profile 2
Profile 3
Profile 4
Profile 5
Profile 6
Profile 7
Profile 8

CDATA
Start profile for cyclic profile switching. Input
CDATA−CYCLE must be HIGH.
Is internally limited to one profile.

C1312

s

1

0

{1}

7 CDATA

Range of profile switching
More x profiles (starting with C1311) will be
processed

C1313

s

0

0
1

Asynchronous stretching/compression
Synchronous stretching/compression

CDATA
Stretching/compression (actual value)

C1314

s

0

0
1

CW rotation
CCW rotation

CDATA
Direction of rotation of master value

l

Set C1313 = 0 if the YSET1 FB is not used

C1315

g

{1 inc}

CDATA
Clock pulse length of the master value

1 Curve 0

... ...

8 Curve 7

Advertising
This manual is related to the following products: