Configuration – Lenze EVS9332xK User Manual

Page 334

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−60

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C1322

s

® Selection list 2 CDATA, CURVEC1

Configuration of digital input signals

1 CDATA−CYCLE

1000 FIXED0

HIGH = Profiles under C1311 and C1312 are
processed cyclically.

2 CDATA−RESET

1000 FIXED0

HIGH: If CDATA−CYCLE = LOW, the input
CDATA−SEL is immediately evaluated; if
CDATA−CYCLE = HIGH, the profile under
C1311 is processed.

3 CDATA−REL−SEL

1000 FIXED0

HIGH: Feed function active

4 CDATA−XRESET

1000 FIXED0

HIGH: Sets master value integrator to 0

5 CDATA−X−TP

1000 FIXED0

HIGH: Sets master value integrator to TP−POS
if input X−TP/E5 = LOW

6 CDATA−HOLD

1000 FIXED0

HIGH: Inhibits profile switching, input has
priority

7 CDATA−LOAD

1000 FIXED0

LOW/HIGH edge activates reloaded/new
profiles

8 CDATA−X−TP/E

5

1000 FIXED0

Selection of TP initiator:
LOW= Initiator at X−TP
HIGH = Connect initiator to terminal X5/E5

9 CURVEC1−HOL

D

1000 FIXED0

HIGH = Outputs AOUT and OUT are stored;
DFOUT = 0

10 CURVEC1−SEL−I

N

1000 FIXED0

Selection − input AIN

«IN

LOW = AIN
HIGH = IN

11 CURVEC1−REL−S

EL

1000 FIXED0

HIGH: feed function active (relative
positioning)

12 CURVEC1−XRES

ET

1000 FIXED0

HIGH: sets the master value integrator to the
value at input CDATA−X−START

13 CDATA−TEACH

1000 FIXED0

HIGH: Teach function is activated

l

Contact Lenze

14 CDATA−TP−DISA

BLE

1000 FIXED0

HIGH: No evaluation of the touch−probe
signals

15 CDATA−SEL−CA

M−MODE

1000 FIXED0

Mode for changing−over between profiles:

l

LOW: During operation, change−over
between profiles takes place at the end of
a profile

l

HIGH: Change−over between profiles can
take place while a motion profile is being
processed
– Only possible with the absolute data

model

– The interpolation points must have an

absolutely equal distribution

– The motion profiles must be congruent

at the point of change−over

– The change−over takes place

immediately when a new profile
number is selected

16 CDATA−TP−EDG

E−SELECT

1000 FIXED0

HIGH: The LOW/HIGH edge of the
touch−probe signal is evaluated
LOW: The HIGH/LOW edge of the
touch−probe signal is evaluated

C1323

g

CDATA, CURVEC1
Display of digital input signals