Code table

8

8.4

l

8.4−22

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0495

s

FEEDBACK N

0

Speed feedback system
Feedback system for the speed controller

0

Resolver at X7

The feedback system can be merged with the
settings of C0490 = 0, 1, 2, 3, 4.

l

A setting of C0495 = 0 sets the rotor
displacement angle in C0058 to −90°

1

Encoder TTL at X8

The selection also sets C0490 to the same
value.

2

Sin/cos encoder at X8

3

Hiperface single−turn absolute value
encoder at X8

4

Hiperface multi−turn absolute value
encoder at X8

C0497 NACT−FILTER

2.0

0.0

{0.1 ms}

50.0 Nact filter time constant

Time constant for actual speed value
C0497 = 0 ms: Switched off

C0499

0

Mode of profile data access protection

0

Read/write protection

1

Only read protection

2

Only write protection

C0500 CAM CHECK

ACTUAL CURVE

0

CAM check of actual profile

0

No CAM check

1

CAM check of all data

2

CAM check, X axis only

3

CAM check, Y axis only

C0503

0

{1}

65535 Password

The allocation of passwords prevents
unauthorised access to profile data and
parameter set

1

0

PIN − profile data

2

0

Master PIN − profile data

C0506

g

1

Version

2

Data field length

Advertising