Configuration, Code table – Lenze EVS9332xK User Manual

Page 301

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−27

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0599 LIMIT LP 1

5.0

1.0

{0.1 %}

10.0 LP1 monitoring

Current limit value for motor phase
monitoring

C0600 FUNCTION

1

0
1
2
3
4
5
15

OUT = IN1
OUT = IN1 + IN2
OUT = IN1 − IN2
OUT = IN1 × IN2
OUT = IN1 / IN2
OUT = IN1 / (100% – IN2)
OUT = IN1 % IN2

ARIT2
Function selection

C0601

s

IN

® Selection list 1 ARIT2

Configuration of analog input signals

1

1000 FIXED0%

ARIT2−IN1

2

1000 FIXED0%

ARIT2−IN2

C0602

g −199.99

{0.01 %}

199.99 ARIT2

Display of analog input signals

1 (C0601/1)

2 (C0601/2)

C0606 MONIT−OC8

2

0
2
3

Trip
Warning
Off

Configuration of the I

2

× t advance warning

The threshold is set in C0127

C0610

s

IN

® Selection list

1

ADD
Configuration of analog input signals

1

1000 FIXED0%

ADD1−IN1

2

1000 FIXED0%

ADD1−IN2

3

1000 FIXED0%

ADD1−IN3

C0611

g −199.99

{0.01 %}

199.99 ADD

Display of analog input signals

1 (C0610/1)

2 (C0610/2)

3 (C0610/3)

C0620 DB1 GAIN

1.00

−10.00

{0.01}

10.00 DB1 gain

Gain of dead band component DB1

C0621 DB1 VALUE

1.00

0.00

{0.01 %}

100.00 DB1 dead band

Dead band of DB1

C0622

s

DB1−IN

1000 FIXED0%

® Selection list 1 DB1

Configuration of analog input signal

C0623 (C0622)

g −199.99

{0.01 %}

199.99 DB1

Display of analog input signal

C0630 MAX LIMIT

100.0

0

−199.99

{0.01 %}

199.99 LIM upper limit

Upper limit of limiter LIM1

C0631 MIN LIMIT

−100.0 −199.99

{0.01 %}

199.99 LIM lower limit

Lower limit of limiter LIM1

C0632

s

LIM−IN

1000 FIXED0%

® Selection list 1 LIM1

Configuration of analog input signal

C0633 (C0632)

g −199.99

{0.01 %}

199.99 LIM1

Display of analog input signal

C0640 DELAY T

20.00 0.01

{0.01 s}

50.00 PT1−1

Setting of the time constant

C0641

s

PT1−1−IN

1000 FIXED0%

à Selection list 1 PT1−1

Configuration of analog input signal

C0642 (C0641)

g −199.99

{0.01 %}

199.99 PT1−1

Display of analog input signal

C0643 DELAY T

0.005 0.003

{0.001 s}

5.000 PT1−2

Setting of filter time constant

Advertising