Configuration – Lenze EVS9332xK User Manual

Page 351

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−77

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C1651

FCODE1476/1

SPC2

1 SPC2−VALUE

1−1

1

Switching point output STATUS−01

2 SPC2−VALUE

1−2

1

Switching point output STATUS−01

3 SPC2−VALUE

2−1

1

Switching point output STATUS−02

4 SPC2−VALUE

2−2

1

Switching point output STATUS−02

5 SPC2−VALUE

3−1

1

Switching point output STATUS−03

6 SPC2−VALUE

3−2

1

Switching point output STATUS−03

7 SPC2−VALUE

4−1

1

Switching point output STATUS−04

8 SPC2−VALUE

4−2

1

Switching point output STATUS−04

9 SPC2−VALUE

5−1

1

Switching point output STATUS−05

10 SPC2−VALUE

5−2

1

Switching point output STATUS−05

11 SPC2−VALUE

6−1

1

Switching point output STATUS−06

12 SPC2−VALUE

6−2

1

Switching point output STATUS−06

13 SPC2−VALUE

7−1

1

Switching point output STATUS−07

14 SPC2−VALUE

7−2

1

Switching point output STATUS−07

15 SPC2−VALUE

8−1

1

Switching point output STATUS−08

16 SPC2−VALUE

8−2

1

Switching point output STATUS−08

C1652

s

SPC2−L−IN

1000 FIXED0INC

® Selection list 3 SPC2

Configuration of input signal

C1653 (C1650)

g 0

1 SPC2

Display of digital input signal

C1654 (C1652)

g −1073741824

{1 inc}

1073741823 SPC2

Display of input signal

C1655 MODE

0

0
1

On / off
Centre/range

SPC2 mode

C1657

−30000

{1 ms}

30000 SPC2

Dead time

1 DEATH TIME

0

... ...

0

4 DEATH TIME

0

C1658 HYSTERESIS

0

−32767

{1 inc}

32767 SPC2

Hysteresis

C1659 FILTER

1

0
1
2
4
8
16

Filter off
Filter 1 ms
Filter 2 ms
Filter 4 ms
Filter 8 ms
Filter 16 ms

SPC2
Filters

C1660 ACT.SEL.

g 0

{1}

8 SELPH1

Display of actual selection

Advertising
This manual is related to the following products: