Configuration – Lenze EVS9332xK User Manual

Page 333

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−59

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C1316

g

{1 inc}

CDATA
Final Y value

1 Curve 0

... ...

8 Curve 7

C1317

0

CDATA

0

Load with ctrl. inhibit

Reloading profiles with controller inhibit

1

Load without ctrl. inhibit

Reloading profiles without controller inhibit

C1318

0

0
1
2

Adapt stop value
Maintain stop value
Maintain sections

TEACH mode

C1319

0

CDATA
Stretching/compression mode

0

DFIN * XFACT / 100%

l

Use of XFACT as multiplier:
– XFACT = +100 %

l

No stretching/compression:
– XFACT = −100 %

l

No stretching/compression but reversal of
direction for X position. The profile will be
processed from the end:
– XFACT > 100 %

l

Leads to compression:
– XFACT < 100 %

1

DFIN * 100% / XFACT

l

Use of XFACT as divisor (reciprocal value):
– Values < 1 % at input XFACT are

internally limited to +1 %

l

If stretching/compression is not wanted:
– Connect XFACT with FIXED100%

(default setting)

C1320

s

® Selection list 1 CDATA, CURVEC1

1

1000 FIXED0%

CURVEC1−AIN

2

1006 FIXED100%

CDATA
CDATA−XFACT
Stretching/compression factor:

l

+100 % = no stretching/compression

l

>100 % = compression

l

<100 % = stretching

3

1000 FIXED0%

CDATA
CDATA−SEL
Profile selection:
0 = profile 0 (1st profile)

C1321

g

1 (C1320/1)

2 (C1320/2)

3 (C1320/3)

Advertising