Commissioning
Basic settings
Entry of motor data
6.5
6.5.4
l
6.5−6
EDSVS9332K EN 8.0−07/2013
Enter the 8−digit resolver designation of the nameplate to achieve the
highest accuracy.
0
9300std088
Fig. 6.5−6
"Feedback" menu of the parameter menu
Procedure
1.
Open the "Parameter menu
® Motor/Feedback ® Feedback" menu.
2.
Click on C0416.
3.
Enter the 8−digit designation
0 of the motor nameplate in the dialog box.
4.
Confirm with "OK".
5.
Save the setting with C0003 = 1.