Installing of the standard device – Lenze EVS9332xK User Manual

Page 57

Advertising
background image

Installing of the standard device

Standard devices in the power range 0.37 ... 11 kW

Mounting in "cold plate" technique

4

4.1

4.1.4

l

4.1−5

EDSVS9332K EN 8.0−07/2013

a

c1

c

c
a

a

c

g

g

g

b1

b1

b1

d

d

d

b

b

b

L

L

L

2

1

0

e

< 75 °C

3

9300std064

Fig. 4.1−3

Dimensions for mounting in "cold plate" technique 0.37 ... 11 kW

9300

Dimensions [mm]

Type

a

b

b1

c

c1

d

e

1)

g

EVS9321−CK
EVS9322−CK

0

78

381

350

48

˘

367

168

6.5

EVS9323−CK
EVS9324−CK

1

97

381

350

67

˘

367

168

6.5

EVS9325−CK
EVS9326−CK

2

135

381

350

105

38

367

168

6.5

1)

For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Apply heat conducting paste before screwing together the cooler and
cooling plate of the drive controller so that the heat transfer resistance is as
low as possible.

1. Fasten the fixing bracket with sheet metal screws 3.5 × 13 mm at the

top and bottom of the drive controller

3.

2. Clean the contact surface of cooler and cooling plate with spirit.

3. Apply a thin coat of heat conducting paste with a filling knife or brush.

– The heat conducting paste in the accessory kit is sufficient for an area

of approx. 1000 cm

2

.

4. Mount the drive controller on the cooler.

Dimensions

Mounting

Advertising