Configuration – Lenze EVS9332xK User Manual

Page 316

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−42

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0902

s

I−LOAD

1000 FIXED0

® Selection list 2 MCTRL

Configuration of activation signal for loading
I−component of speed controller

C0903

s

P−ADAPT

1006 FIXED0%

® Selection list 1 MCTRL

Configuration of input signal for adaptation
of phase controller

C0906

g −199.99

{0.01 %}

199.99 MCTRL

Display of analog input signals

1 (C0890)

2 (C0891)

3 (C0892)

4 (C0893)

5 (C0895)

6 (C0896)

7 (C0898)

8 (C0901)

9 (C0903)

C0907

g

MCTRL
Display of digital input signals

1 (C0897)

2 (C0899)

3 (C0900)

4 (C0902)

C0908 (C0894)

g −2147483647

{1 inc}

2147483647 Set phase signal

l

1 rev. = 65536 inc.

C0909 SPEED LIMIT

1

1
2
3

+/− 175 %
0 ... +175 %
−175 ... 0 %

Limitation of direction of rotation for the
speed setpoint

C0920

s

REFC−ON

1000 FIXED0

® Selection list 2 REFC

Configuration of digital input signal
Activation of homing function

C0921

s

REFC−MARK

1000 FIXED0

® Selection list 2 REFC

Configuration of digital input signal
Digital reference switch

C0922

s

REFC−PHI−IN

1000 DFSET−PSET

® Selection list 3 REFC

Configuration of phase input signal

C0923

s

REFC−N−IN

1000 DFSET−NOUT

® Selection list 1 REFC

Configuration of speed input signal

C0924

s

REFC−POS−LOA
D

1000 FIXED0

® Selection list 2 REFC

Configuration of digital input signal
Control "Set position"

C0925

s

REFC−ACTPOS−I

1000 FIXED0INC

® Selection list 3 REFC

Configuration of input signal for "Set
position"

C0926

g −2147483647

{1 inc}

2147483647 REFC

Display of input signals

1 (C0925)

2 (C0922)

3 ACTPOS

Actual position

4 TARGET

Target position

C0927

g

REFC
Display of digital input signals

1 (C0920)

2 (C0921)

3 (C0924)

Advertising