Safety relay ksr, Safety engineering – Lenze EVS9332xK User Manual

Page 429

Advertising
background image

Safety engineering

Safety relay KSR

11

11.3

l

11.3−1

EDSVS9332K EN 8.0−07/2013

11.3

Safety relay K

SR

Technical data

Terminal

Description

Field

Values

X11/K32
X11/K31
X11/33
X11/34

Safety relay K

SR

1st disconnecting path

Coil voltage at +20 °C

DC 24 V (20 ... 30 V)

Coil resistance at +20 °C

823

W ±10 %

Rated coil power

Approx. 700 mW

Max. switching voltage

AC 250 V, DC 250 V (0.45 A)

Max. AC switching capacity

1500 VA

Max. switching current (ohmic load)

AC 6 A (250 V), DC 6 A (50 V)

Recommended minimum load

> 50 mW

Max. switching rate

6 switchings per minute

Mechanical service life

10

7

switching cycles

Electrical service life

at 250 V AC
(ohmic load)

10

5

switching cycles at 6 A

10

6

switching cycles at 1 A

10

7

switching cycles at 0.25 A

at 24 V DC
(ohmic load)

6 × 10

3

switching cycles at 6 A

10

6

switching cycles at 3 A

1.5 × 10

6

switching cycles at 1 A

10

7

switching cycles at 0.1 A

Advertising
This manual is related to the following products: