Troubleshooting, Status display via controller leds, Troubleshooting and fault elimination – Lenze EVS9332xK User Manual

Page 397

Advertising
background image

Troubleshooting and fault elimination

Troubleshooting

Status display via controller LEDs

9

9.2

9.2.1

l

9.2−1

EDSVS9332K EN 8.0−07/2013

9.2

Troubleshooting

A breakdown can be detected quickly via the LEDs at the controller or via the
status information at the keypad.

Analyse the error using the history buffer. The list of fault messages gives
you advice how to remove the fault. (

9.3−1)

9.2.1

Status display via controller LEDs

During operation the operating status of the controller is shown by 2 LEDs.

LED

Operating status

Red



Green

‚

Off

On

Controller enabled

On

On

Mains switched on and automatic start
inhibited

Off

Blinking
slowly

Controller inhibited

Blinking
quickly

Off

Undervoltage or overvoltage

Blinking
slowly

Off

Fault active

Detecting breakdowns

Analysing errors

Advertising