Rockwell Automation 8520-MUM 9/Series CNC Mill Operation and Programming Manual Documentation Set User Manual
Page 156

Editing Programs Online
Chapter 5
5-42
2.
Press the {COPY PRGRAM} softkey.
REFORM
MEMORY
ACTIVE
PRGRAM
EDIT
PRGRAM
RESTRT
PRGRAM
DISPLY
PRGRAM
COPY
PRGRAM
VERIFY
PRGRAM
PRGRAM
COMENT
DELETE
PRGRAM
RENAME
PRGRAM
INPUT
DEVICE
(softkey level 2)
3.
Cursor down to or enter the program name of the program to be
copied, followed by a comma and a name for the duplicate program.
COPY: FROM_NAME,TO_NAME
4.
Press the {MEM TO MEM} softkey.
MEM TO
PORT A
FROM A
TO MEM
MEM TO
PORT B
FROM B
TO MEM
MEM TO
MEM
(softkey level 3)
The following message will appear:
“FROM: (source program name)
“TO:
(new programs name)
Important: The control will display the active communication parameters
if one of the communication ports has been chosen. If the communication
port parameters do not match that of the peripheral device they must be
altered for a successful copy to take place. For details on setting
communication port parameters see chapter 9.
5.
Select softkey {COPY YES} or {COPY NO}. {COPY YES} copies
the part program, while {COPY NO} aborts the copy operation.
COPY
YES
COPY
NO
(softkey level 4)
6.
If you want to verify that the copied program identically matches the
original, use the {VERIFY PRGRAM} feature discussed in chapter 9.