Using Transfer Line Cycles

Chapter 31

31-17

Part program templates were loaded on your control when it was shipped
from Allen-Bradley. They are however stored in a volatile area of control
memory (requires power to be maintained). Common causes for losing the
part program templates stored in this area are:

Memory Lost Because:

Detail:

Power Loss

The control comes standard with 5 to 7 days
of supercap power to maintain volatile
memory. You can purchase an optional
battery backup that will maintain this memory
for 6 months without power.

Format RAM Disk

Various control conditions can result in
memory becoming corrupt. When this
occurs you must perform a reformat
operation on the volatile memory area which
removes any part program templets.

You can identify that part program templates have been lost by trying to
create a part program using the QuickView screens as discussed on page
31-12. When you select the part program type to create the control will
display the error “PART PROGRAM TEMPLATE MISSING”. This
message tells you that the transfer line part program templates are missing
or corrupted.

Replacing the Part Program Templates

If for some reason the part program templates are lost, follow this
procedure to re-install the project. You must first obtain an ODS backup of
the T-Line-9 standard program templates from the Allen- Bradley Motion
Control Division. This ODS backup project is included on floppy disk
with this documentation or can be obtained using the Allen-Bradley
Motion Control Division electronic bulletin board (216)-646-3963.

The transfer line project can be restored using a personal computer with
the Allen-Bradley ODS software installed on its hard drive. Contact your
Allen-Bradley sales office if you do not have a copy of the ODS software.

Restore the project to ODS as described in your ODS user’s manual. See
the section titled Restoring a Backed up Project in the chapter titled Using
ODS Project Management
. The ODS workstation will copy the
transfer line AMP, PAL, and part program templates from the ODS backup
project titled Tran230.

The following procedure describes the download procedure for restoring
the part program templates to the control.

31.1.5
Reloading Part Program
Templates