Basic Control Operation

Chapter 2

2-23

After powering up the control or performing a control reset operation (see
page 2-4), the control assumes a number of initial operating conditions.
These are listed below:

Initial Password Access is assigned to the level that was active when
power was turned off (provided that level is a power-up level selected in
access control). If the active level when power is turned off is not a
power-up level, then the control defaults to the next lower level that is a
power-up level. See page 2-25 on access control.

The control is placed in E-Stop. The control is not allowed to come out
of E-Stop if the default AMP is loaded at power-up, or if there is no
PAL program loaded in the system. An appropriate error message is
displayed.

The control defaults to one G-code from each of these groups
(as set in AMP):

Modal Group:

G-code

1

G00

Rapid traverse

G01

Linear interpolation

2

G17

Plane Selected

G18

Plane Selected

G19

Plane Selected

3

G90

Absolute

G91

Incremental

4

G22

Programmable Zone 2 and 3 (On)

G22.1

Programmable Zone 2 (Off) 3 (On)

G23

Programmable Zone 2 and 3 (Off)

G23.1

Programmable Zone 2 (On) 3 (Off)

5

G94

Feed per minute

G95

Feed per revolution

6*

G70

Inch mode

G71

Metric mode

18

G07

Radius Programming Mode

G08

Diameter Programming Mode

* This G code group is only established at power up. A control reset
will not change the last programmed state of this modal G code group.

To show the current operating conditions at any time, access the G-code
status screen as described in chapter 8. If you do this immediately after
power-up, it shows the initial operating conditions selected in AMP along
with other control power-up default conditions.

2.5
Control Conditions at
Power-Up