Running a Program
Chapter 7
7-3
To enter a sequence number to stop execution:
1.
Press the {PRGRAM MANAGE} softkey. Note that a program must
have already been selected for automatic execution as discussed in
section 7.3.
(softkey level 1)
PRGRAM
MANAGE
OFFSET MACRO
PARAM
QUICK
CHECK
SYSTEM
SUPORT
FRONT
PANEL
ERROR
MESAGE
PASS-
WORD
SWITCH
LANG
2.
Press the {ACTIVE PRGRAM}.
REFORM
MEMORY
ACTIVE
PRGRAM
EDIT
PRGRAM
RESTRT
PRGRAM
DISPLY
PRGRAM
COPY
PRGRAM
VERFY
PRGRAM
PRGRAM
COMENT
DELETE
PRGRAM
RENAME
PRGRAM
INPUT
DEVICE
(softkey level 2)
3.
Press the {SEQ STOP} softkey.
(softkey level 3)
DE-ACT
PRGRAM
SEARCH MID ST
PRGRAM
T PATH
GRAPH
T PATH
DISABL
SEQ
STOP
TIME
PARTS
4.
Key in the sequence number where automatic operation in the part
program is to stop, then press the [TRANSMIT] key.
Important: The control will stop automatic operation after it completes
the commands in the block.
5.
Press the <CYCLE START> button to continue execution of the
program from the point at which program execution was stopped.