Error and System Messages

Appendix B

B-30

Message

Description

NO PROGRAM TO RESTART

There is no program to restart. The previous program was either completed or cancelled.

NO RECIPROCATION DISTANCE

A reciprocation interval of zero (0) was programmed for a grinder reciprocation fixed cycle.

NO RECIPROCATION FEEDRATE

The reciprocation feedrate, E-word, required during a grinder reciprocation fixed cycle was not
programmed.

NO SPINDLE ASSIGNED TO THIS PROCESS

A process attempted to activate virtual or cylindrical mode and that process has no spindle
assigned to it via AMP.

NO STRING INPUT

A program search operation was requested and no string to search for has been entered. Key
in the required search string, and press the [TRANSMIT] key to enter a search string.

NO TOOL GROUP PROGRAMMED

A block that loads data into the tool management table does not contain the parameter that
determines the tool group number corresponding to the other data in the block. The group
number is programmed using the P-word.

NO TOOL NUMBER PROGRAMMED

A block that loads data into the tool management table does not contain the parameter that
determines the tool number corresponding to the other data in the block. The tool number is
programmed using the T-word.

NO UNEXPIRED TOOL AVAILABLE

A request for a tool group was made, and all of the tools in that tool management group have
expired their tool lives. Either reset the tool life for the tools, or install new tooling.

NON_CONSECUTIVE/TOO MANY FITTED AXES

More than the allowable number of axes may have been assigned in AMP or an unfitted axis
was assigned between two fitted axes. You can assign only fitted axes consecutively in AMP.

NON-LINEAR AXIS IN PLANE DEFINITION

The current axis plane is illegal because a non-linear axis (rotary) has been assigned to the
plane in AMP.

NOT ALIGNED

During the power--up alignment procedure, either the 1326 motor (connected to a 9/440HR) is
misaligned or the SINCOS device’s memory is corrupt.

NOT ALLOWED IN ANGLED WHEEL MODE

The axes can not be moving when you change to angled wheel mode. Also the axes involved in
angled wheel motion must be homed before you can enter angled wheel mode. Other features,
such as block retrace or jog retract also must not be active when changing mode.

NOT ALLOWED - G41/G42 ACTIVE

An attempt was made to perform some operation or program some feature that cannot be
performed when cutter compensation or TTRC is active (G41 or G42). Cancel compensation by
programming a G40 block before performing the operation.

NOT ALLOWED FROM MDI

Certain programming commands are not allowed from MDI (GOTO, WHILE, etc.).

NOT ALLOWED ON DUAL/SLAVE AXIS

A G26 was programmed on a dueled axis. The G26 feature is incompatible with the dual axis
feature.

NOT ALLOWED - THREADING ACTIVE

An attempt was made to perform some operation (typically a spindle speed adjustment) that is
not allowed when cutting a thread. This includes all forms of threading, including single pass or
multiple pass threads.

NOT IN G10L3 MODE

A G11 block was programmed that cancels G10L3 data setting when the control is not in the
G10L3 data setting mode. G10L3 is used to set the tool management table data.

NUMBER IS OUT OF RANGE

An attempt was made to perform a calculation using the paramacro features or the calculator
features that contains a number longer than 11 characters.

NUMBER OF MOTORS/SPINDLE CONFIG ERROR

This is error indicates AMP is incorrectly configured for the 9/Series hardware. Typical AMP
configuration errors that generate this error include:

You have AMPed more motors than the current hardware supports.
You have indicated there are servo motors attached to servo boards that don’t exist (the
9/230 and 9/440 are configured as if they have only one servo card).
You have configured too many spindles (1 on 9/230, 2 on 9/260 and 9/440, 3 on 9/290).
Too few axes were configured for the indicated number of motors on the boards or
too few servos were configured for indicated number of motors on the boards.

NUMERIC VALUE MISSING

The numeric value associated with the programmed word is missing. There is an AMP
parameter that determines whether a missing numeric is assumed to be zero or if it will generate
this error.