Rockwell Automation 8520-MUM 9/Series CNC Mill Operation and Programming Manual Documentation Set User Manual

Page 756

Advertising
background image

Paramacros

Chapter 28

28-56

POPEN

This command affects a connection to the output device by sending a DC2
control code and a percent character “%” to the RS-232 interface. This
command must be specified prior to outputting any data. After this
command, the control outputs any following program blocks including the
parameter values that are used in them.

The format for a POPEN block is:

POPEN;

PCLOSE

This command disconnects the control from the output device by sending a
DC4 control code and a percent character “%” to the RS-232 interface.
This command must be specified after all data have been output. This
command only executes provided that the corresponding POPEN
command has previously been executed.

The format for a PCLOSE block is:

PCLOS;

BPRNT

This command initiates the outputting of a variable number of parameter
values in binary format. An end of block character is output at the
completion of outputting all of the specified values. This command will
not be executed if the POPEN command has not been issued.

The format for the BPRNT block is:

BPRNT [ s #p[d]...];

Where :

Is :

s

is any alpha-numeric string of characters, including all letters, +, -, *, and /
symbols. Note that the * is output as a space character. This string is optional
and does not need to be programmed in the block.

#p

This is any valid parameter number. Note that the parameter number must have
the # sign before it.

d

This indicates the number of digits after the decimal point to be output.

There may be as many S and #P in a block as desired provided that the
length of the block does not exceed the maximum block size.

Example 28.22

Sample of a BPRNT Block

BPRNT[INSTALL*TOOL*NUMBER*1#123[4]*PRESS*CYCLE*STOP**#234[2]];

Advertising