Rockwell Automation 8520-MUM 9/Series CNC Mill Operation and Programming Manual Documentation Set User Manual

Page 92

Advertising
background image

Offset Tables and Setup

Chapter 3

3-18

Important: Once the control begins executing a G10 program that has
been previously generated, it will clear any data that already exists in the
offset table being updated by that G10 command. This makes it
impossible for a G10 block to simply add a few offset values. A G10
program must load the entire offset table each time it is run. Note that tool
geometry and tool wear tables are separate offset tables. Loading data into
one does not clear the other.

To backup the offset tables follow the directions below:

1.

Press the

{OFFSET}

softkey.

(softkey level 1)

PRGRAM

MANAGE

FRONT

PANEL

MACRO

PARAM

QUICK

CHECK

SYSTEM

SUPORT

OFFSET ERROR

MESAGE

PASS-

WORD

SWITCH

LANG

2.

Press the

{BACKUP OFFSET}

softkey. This softkey backs up the

currently active tool length offset axis. If you’re using offsets on
more than one axis, each axis must be selected and backed up
separately. The backup offset screen shown in Figure 3.6 is displayed.

(softkey level 2)

WORK

CO-ORD

TOOL

WEAR

TOOL

GEOMET

TOOL

MANGE

RANDOM

TOOL

COORD

ROTATE

BACKUP

OFFSET

SCALNG

Advertising