DRESSER WARNING LIMIT REACHED

The axis specified as the dresser axis has been dressed smaller than the dresser warning limit
value as specified on the dresser status page.

DRILL AXIS CONFIGURATION ERROR

The drilling axis is not a currently configured machine axis. On dual processing controls this
message may result when the drilling axis is in another process. The drilling axis must be a
configured axis in the current process and should not be the slave of a dual axis (drill axis
should be the master axis for dual group). On machines with dual axes, this message can
mean the axis configured in AMP as the fixed-drilling axis is a slave axis. The drill axis should
be the master axis.

DUAL AXES MASTER&SLAVE PROCESS NOT SAME

When configuring a dual axis on a dual processing system, configure AMP so all axes in the
dual axis group are in the same source process even if the dual axis group is shared.

DUAL AXES PARK LOGIC CANNOT CHANGE

An attempt was made, using dual axes, to change the current park status. At this point, the
request will not be allowed.

DUAL GROUP AXES MUST HAVE SAME ROLLOVER

All rotary axes in a dual axes group must have the same rollover value. These rollover values
are set in AMP.

DUAL LATHE-MUST USE PROCESS 1,2

Dual lathe must have the active processes be the first 2 available in AMP; 3 or 4 should not be
configured as an active process.

DUAL MASTER&SLAVE RAD/DIAM CONFIG ERR

The slave of a dual group has been defined as a diameter axis. The OEM must define the
master to be a diameter axis and the system will change the slave to be a diameter axis. When
the group is decoupled the slave will continue to take on the master’s rad/diam traits.

DUAL PLANE CONFIGURATION ERROR

In AMP you have defined a plane with an axis and a master and a slave in the wrong order. For
example: If the system has 4 axes YXZU and ZU are duals, if an AMPed plane is ZX, then UX
can not be and AMPed plane. It must be XU (refer to your AMP reference manual for details).

DUAL SLAVE OR SPLIT AXIS NOT ALLOWED

Neither a dual slave, nor a split axis (deskew axis) may be programmed in a G24, G25, or G26
block.

DUALS CANNOT CHANGE OFFSETS IN CIRCULAR

An attempt was made, using dual axes, to account for an offset change in a circular move.
Dual offset changes can only be made in linear blocks.

DUALS ONLY ALLOWING SINGLE AXIS HOME

An attempt was made to home multiple axes in a dual group when PAL only allows one axis at a
time to be homed. PAL can be changed to allow homing of multiple axes in a dual group.

DUALPORT PTO TEST FAILED

The Dualport failed the diagnostic test and the bootstrapping operation is skipped. Consult
Allen-Bradley customer support services.

DUPLICATE 1394 SLOT

The 1394 rack ID and slot number AMP entries are the same for two or more servos. Each axis
module in a 1394 rack must have an individual address.

DUPLICATE 7300 PATTERN NAME

An attempt was made to enter a 7300 pattern name that already exists.

DUPLICATE DUAL MASTER NAMES

Both dual master axes names have the same letter.

DUPLICATE I/O RING DEVICE

Two or more of the same type of device on the I/O ring have the same device address switch
setting.

DUPLICATE PROGRAM

An attempt was made to rename a program in control memory using the same program name
(or number) of another program already in memory.

DUPLICATE PROGRAM NAME

An attempt was made to store or copy a program in control memory using the same program
name (or number) of another program already in memory.

DWELL VALUE NOT PROGRAMMED

A G04 Dwell or a parameter requesting a dwell at hole bottom in a fixed drilling cycle was
programmed with no value assigned to the length of the dwell.

E

(E) AND (F) IN SAME BLOCK

In a G32 block (Lathe A) or G33 block (Lathe B & C), both leads were programmed in the same
block.

EMPTY PROGRAM WAS DELETED FROM DIRECTORY

The current program being edited was saved and contained no program blocks. This program
was deleted from the control’s program directory.