Skip, Gauge, and Probing Cycles

Chapter 27

27-26

This feature:

Used with G26 adaptive depth:

Dual and De-skew axes

Is incompatible with the adaptive depth probe. An error is
generated when you attempt to run an adaptive depth
cycle if one of these types of axes are configured as the
adaptive depth axis.

Mid Start/ Program Restart

If motion to the block that is selected for Mid Start/Program
Restart generates a move that fires the depth probe, a
unexpected depth probe trip will occur. You can not use
these features to start at any block that would normally
have been executed with the depth probe tripped.

Polar Programming (G16)

You can not program a G26 block if the adaptive depth axis
is in the current plane and the control is in polar
programming mode.

If you would like to monitor your adaptive depth probe position, you can
view the probe location on the adaptive depth probe axis monitor screen.
The system installer can also make this information available through a
PAL display page by monitoring adaptive depth axis information. Refer to
your Integration and Maintenance Manual for details on using the monitor
pages. Your system installer may have password protected the monitor
softkey.