Rockwell Automation 8520-MUM 9/Series CNC Mill Operation and Programming Manual Documentation Set User Manual

Page 785

Advertising
background image

Chapter 30
Using a 9/Series Dual--processing System

30-17

Figure 30.5

Measuring Interference Checking Areas

Machine

Home

Process 1

Area 1

Area 2

+X

Z and U

X Plus
Area 1

X Minus
Area 1

Z Plus
Area 1
Z Minus
Area 2

Z Minus
Area 1

X Plus
Area 2

X Minus
Area 2

Z Plus
Area 2

Machine
Coordinate
System Zero Point
(Both Processes)

Machine Home
Process 2

Area 1

+U

Process 2

Process 1

U Minus
Area 1

U Plus
Area 1

W Plus
Area 1

W Minus
Area 1

Important: These areas are measured from the machine coordinate zero
point
to the extremes of the fixture encompassed by the zone when the
machine is at home. The machine coordinate system zero point and
machine home are frequently not the same point on the machine. Machine
home is a fixed mechanical position established by the homing sequence
off hardware homing switches. The machine coordinate system zero point
is established in AMP and referenced from the machine home point (see
chapter 11 for details). Refer to your system installer’s documentation for
information regarding the location of machine coordinate system zero. For
interference checking to function properly, both processes must have the
same zero point
, but they can have different home locations.

Advertising