5 programmable zone table – Rockwell Automation 8520-MUM 9/Series CNC Mill Operation and Programming Manual Documentation Set User Manual

Page 95

Advertising
background image

Offset Table and Setup

Chapter 3

3-21

The programmable zone feature provides a means to prevent tool motion
from entering or exiting a designated area. For details on programmable
zones see chapter 12.

This table contains the values for programmable zones 2 and 3. These
values define the boundaries for the programmable zones and are
referenced from the machine coordinate system.

Important: These values may also be entered in AMP by the system
installer. Programmable zone 3 table values may also be modified by
programming a G22 command (see chapter 12).

1.

To display or alter the values in the programmable zone table follow
the steps below:

(softkey level 1)

PRGRAM

MANAGE

OFFSET MACRO

PARAM

QUICK

CHECK

SYSTEM

SUPORT

FRONT

PANEL

ERROR

MESAGE

PASS-

WORD

SWITCH

LANG

2.

Press the {PROGRAM PARAM} softkey.

(softkey level 2)

PRGRAM

PARAM

AMP

DEVICE

SETUP

MONI-

TOR

TIME

PARTS

PTOM

SI/OEM

3.

Press the {ZONE LIMITS} softkey to display the programmable
zone table as shown in Figure 3.7.

(softkey level 3)

ZONE

LIMITS

F1-F9

MILCYC

PARAM

PROBE

PARAM

3.5
Programmable Zone Table

Advertising