Rockwell Automation 8520-MUM 9/Series CNC Mill Operation and Programming Manual Documentation Set User Manual

Page 162

Advertising
background image

Editing Programs Online

Chapter 5

5-48

To fill in the encryption/decryption table by using the {REVRSE
FILL} softkey, press the {REVRSE FILL} softkey. Pressing this
softkey automatically fills the spaces of the encryption/decryption
table in a reverse order as shown below:

UPDATE

& EXIT

STORE

BACKUP

REVRSE

FILL

ENTER A CHARACTER:

= ]

. = Q

9 = F

D = ;

O = 0

Z = #

” = [

/ = P

: = E

E = :

P = /

[ = ”

# = Z

0 = O

; = D

F = 9

Q = .

] =

% = Y

1 = N

< = C

G = 8

R = -

& = X

2 = M

= = B

H = 7

S = ’

( = W

3 = L

> = A

I = 6

T = +

) = V

4 = K

? = @

J = 5

U = *

* = U

5 = J

@ = ?

K = 4

V = )

+ = T

6 = I

A = >

L = 3

W = (

’ = S

7 = H

B = =

M = 2

X = &

- = R

8 = G

C = <

N = 1

Y = %

3.

Enter the encryption/decryption characters one at a time, press the
{REVRSE FILL} softkey, or modify the reverse filled screen.

4.

Press the {UPDATE & EXIT} softkey to update and exit the
encryption/decryption table.

UPDATE

& EXIT

STORE

BACKUP

REVRSE

FILL

(softkey level 3)

When you press the {UPDATE & EXIT} softkey, the control does a
compile/check of the encryption/decryption table to determine that
no duplicate characters exist and that no characters were left blank.

If a character is:

the control displays:

and moves the cursor:

entered twice

“CHARACTERS CAN ONLY BE ENTERED ONCE”

to the first occurrence of that character in the
encryption/decryption table

left blank

“NO LOCATIONS CAN BE LEFT EMPTY”

to the first blank location in the encryption/decryption table

Advertising