MN-CDM625A

Updating Firmware

Revision 3

4–9

4.3.3

Perform the Ethernet FTP Upload Procedure

You may proceed with the firmware update procedure under the assumptions that:

Your CDM-625A is connected to a user-supplied, Windows-based PC, and:

o Your PC serial port is connected to the CDM-625A “Remote Control” port

with a standard user serial cable.

o Your PC Ethernet port is connected to a CDM-625A “10/100 Ethernet”

port with a user-supplied hub, switch, or direct Ethernet cable

connection.

o Your PC is running a terminal emulation program (for operation of the

CDM-625A Serial Interface) and a compatible Web browser (for operation

of the CDM-625A HTTP Interface).

Your CDM-625A firmware and Ethernet Traffic/Management IP Address has

been noted using either the CDM-625A Serial Interface or the CDM-625A

HTTP Interface ‘Admin | Firmware | Base Modem’ and ‘Configuration | LAN |

IP’ pages, respectively.

The latest firmware files have been downloaded or otherwise received from

Comtech EF Data and are available on the User PC in an accessible temporary

folder.

1)

Send a “ping” command to confirm proper connection and communication between the

User PC and the CDM-625A:

Use Command-line: Type “ping xxx.xxx.xxx.xxx” at the Command-line prompt (where

xxx.xxx.xxx.xxx’ is the unit Ethernet Traffic/Management IP Address).

• You may alternately use the CDM-625A HTTP Interface ‘Admin | Utilities’ page, as

shown in this example:

For either method, the response should confirm whether the unit is properly connected

and communicating.

2)

Use Command-line to transfer (FTP) the files from the User PC to the CDM-625A: