Comtech EF Data CDM-625A User Manual

Page 365

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Serial-based Remote Product Management

Revision 3

8–53

Parameter

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Offline Unit Status N/A

8 bytes

Query only. (1:1 set-up)

This query is sent to the online modem of a 1:1 pair. It provides access to the fault status information (FLT?) of the offline

modem. This is the only way to interrogate the status of an offline modem at the distant-end of a link. The response

format may be:

No_1for1=Indicates that no 1:1 system has been detected. Presence of a 1kHz signal from the CRS-150 is used to

indicate a 1:1 set-up;

No_Comms=Indicates that a 1kHz signal has been detected, but that there is no (or not yet) a response for the

modem;

abcdef=The FLT? response information from the offline 600L unit; or

abcdefghxx=The FLT? response information from the offline CDM-625A unit.

N/A

OUS?

OUS=xxxxxx

(see Description of

Arguments)

Faults and

Status

N/A

10 bytes

Query only.

Returns the current highest-priority fault and status codes for the Unit (hardware), TX Traffic, RX Traffic, and ODUs:

a=Unit status:

0=No faults

1=Power supply fault, +5 volts

2=Power supply fault , +12 volts

3=Power supply fault, -5 volts

4=Power supply fault, +3.3 volts

5=Power supply fault, -12 volts

6=Power supply fault, +2.5 volts

7=Top Card comms

8=Tx synthesizer lock

9=Rx synthesizer

A=Top card load fail

B=TPC/LDPC FPGA load fail

C=HDLC FPGA load fail

D=CnC FPGA load fail

E=VersaFEC FPGA load fail

F=Calibration data missing

Exception – 600L: F=Rx synthesizer2

G=Reference unlocked (Note: Tx off)

H=TXDCM fail

I=Over Temperature Alarm

J=Packet Processor mailbox fault

K=Fractional CnC use only

L=Top Card 3.6 Volt fault

M=Top Card 5.5 Volt fault

N=Calibration data transfer error

P=VersaFEC-2 FPGA load fail

b=Tx Traffic status:

0=Tx traffic OK

1=No clock from terrestrial interface

2=Tx FIFO slip

3=AIS detected on incoming data

4=AUPC upper limit reached

5=(Hi-Stab) No External Ref found (no activity)

6=BUC summary alarm (if ABA enabled)

7=G.703 Loss of Signal (only valid in Clock Extend Mode)

N/A

FLT?

FLT=abcdefghxx

(see Description of

Arguments)

Exception –

600L Emulation format:

FLT=abcdef

Advertising