Comtech EF Data CDM-625A User Manual

Page 343

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Serial-based Remote Product Management

Revision 3

8–31

Parameter

Command

(Instruction

& Qualifier)

Length of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

…Retrieve next

five unread

Stored Events

(cont.)

C=Fault Code number, as in FLT? or Info Code, which may be:

0=Power Off

1=Power On

2=Log Cleared

3=Global Config Change

4=Redundancy Config Change

5=Fractional CnC License is expiring.

6=Time Limited CnC License is expiring.

7=Fractional CnC is in use.

ddmmyy=date stamp.

hhmmss=time stamp.

Notes:

1) If there are less than five retrievable events, the remaining positions are padded with zeros.

2) If there are no new events, the response is RNE*.

Clear All

Stored Events

CAE=

None

Command only.

This command takes no arguments. Forces the modem to clear the firmware events log.

Example: <0/CAE=

CAE=

CAE?

CAE*

CAE#

N/A

N/A

Initialize Stored

Events Pointer

IEP=

None

Command only.

Resets internal pointer to allow RNE? queries to start at the beginning of the stored events log.

IEP=

IEP#

N/A

N/A

Statistics

Sample Interval

SSI=

1 byte, numerical Command or Query.

Sets or returns the sample interval for the Statistics Logging Function in the form x, where:

x=0 thru 9 in 10 minute steps.

Note: Set this parameter to 0 thru disable the statistics logging function.

Example: <0/SSI=3 (interval is set at 30 minutes)

SSI=

SSI?

SSI*

SSI#

SSI?

SSI=x

(see Description of

Arguments)

Number of

Unread stored

Statistics

N/A

3 bytes

Query only.

Returns the number of stored statistics that remain unread over remote control, in the form xxx, where xxx=000-255.

Example: <0/NUS? >0/NUS=187

N/A

NUS?

NUS=xxx

(see Description of

Arguments)

Retrieve next

five unread

Stored

Statistics

N/A

135 bytes

Query only.

Returns the oldest five stored Statistics that have not yet been read, in the form [CR]sub-body[CR]sub-body[CR]

sub-body[CR]sub-body[CR]sub-body where:

For all non-ACM modes, the statistics sub-body is defined as AA.ABB.BC.CD.Dddmmyyhhmmss where:

AA.A=Minimum Eb/No during sample period.

BB.B=Average Eb/No during sample period.

C.C=Maximum Tx Power Level Increase during sample period.

D.D=Average Tx Power Level Increase during sample period.

ddmmyy=date stamp.

hhmmss=time stamp.

In VersaFEC ACM (IP-ACM) mode, the statistics sub-body is defined as AA.ABB.BC,DE,Fddmmyyhhmmss,

where:

AA.A=Minimum SNR during sample period.

BB.B=Average SNR during sample period.

C=IP-ACM Rx ModCod that was current at time the statistic entry was logged.

D=Maximum Rx ModCod in hex during sample period.

E=Minimum Rx ModCod in hex during sample period.

N/A

RNS?

RNS=[CR]sub-

body[CR]sub-

body[CR]

sub-body[CR]sub-

body[CR]sub-body

(see Description of

Arguments)

Advertising