9 miscellaneous, 10 approvals – Comtech EF Data CDM-625A User Manual

Page 78

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Introduction

Revision 3

1–34

1.4.9

Miscellaneous

Front Panel

Tactile keypad, 6 keys (up, down, left, right, ENTER, CLEAR)

Vacuum Fluorescent Display (blue) – two lines @ 40 characters/line

Loopbacks

Internal IF loopback, RF loopback, digital loopback, and inward/outward loopback

Fault relays

Hardware fault, Rx and Tx Traffic Alarms, Open Network Backward Alarms

Type: Form C Contacts. Rating: Up to ±50 volts, maximum 0.5 Amp

M&C Interface

EIA-232 and EIA-485 (addressable multidrop, 2-wire or 4-wire) or Ethernet (10/100 BaseT)

M&C Software

Serial comms, SNMP, Telnet, HTTP (Web Server)

Firmware update

FTP protocol via Ethernet port

Dimensions

1RU high, 17.65 inches (448 mm) deep

Weight

10.5 lbs (4.8 kg) maximum (All option cards and 48V BUC supply installed)

AC consumption

48 watts (typical, TPC/LDPC Codec module installed), 68 watts (maximum)

280 watts (typical, TPC/LDPC Codec module and 48 volt BUC supply installed, 300 watts (max)

AC operating voltage

100-240 VAC Nominal - autosensing

90-264 VAC Maximum

DC consumption (option)

As above (AC consumption)

DC operating voltage

20-60 VDC Nominal

36-60 VDC Maximum

Operating temperature

32°-122°F (0°-50°C)

‘ER’ VERSION: 32°-140°F (0°-60°C)

1.4.10 Approvals

“CE” as follows:

EN 55022 Class B (Emissions)

EN 50082-1 (Immunity)

EN 60950-1 (Safety)

EN 61000-3-2

EN 61000-3-3

EN 61000-4-2

EN 61000-4-4

EN 61000-4-5

EN 61000-4-6

EN 61000-4-8

EN 61000-4-9

EN 61000-4-11

EN 61000-4-13

FCC

Federal Communications Commission Federal Code of Regulation FCC Part 15, Subpart B.