Comtech EF Data CDM-625A User Manual
Page 327

CDM-625A Advanced Satellite Modem
MN-CDM625A
Serial-based Remote Product Management
Revision 3
8–15
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
Tx Carrier
State
TXO=
1 byte, 0 thru 9
Command or Query.
Sets or returns Tx Carrier State in the form x, where:
0=OFF due to front panel or remote control command
1=ON
2=RTI (receive/transmit inhibit), timeout=10 seconds
3=OFF due to ext H/W Tx Carrier- Off control *
4=OFF due to BUC or High-Stability Ref warm-up *
5=Carrier controlled by STDMA Controller *
6=RTI (receive/transmit inhibit), timeout=1 second
7=RTI (receive/transmit inhibit), timeout=2 seconds
8=RTI (receive/transmit inhibit), timeout=4 seconds
9=RTI (receive/transmit inhibit), timeout=7 seconds
Note: Arguments indicated with a * are status-only. They are not valid as a command, and are not indicated in MGC?
response.
Example: <0/TXO=1 (Tx Carrier ON)
TXO=
TXO?
TXO*
TXO#
TXO?
TXO=x
(see Description of
Arguments)
Tx Alpha
TXA=
1 byte, 0 thru 5
Command or Query.
Sets or returns Tx Alpha Filter Rolloff Factor in the form x, where:
0=0.35
1=0.25
2=0.20
3=0.15
4=0.10
5=0.05
Example: <0/TXA=0 (Tx filter rolloff factor is 0.35)
TXA=
TXA?
TXA#
TXA?
TXA=x
(see Description of
Arguments)
Power Level
Mode
(was AUPC
Enable)
AUP=
1 byte, 0 thru 3
Command or Query.
Sets or returns Power Level Mode in the form x, where:
0=MANUAL mode (AUPC disabled) – Normal power mode
1=AUPC enabled.
2=MANUAL-LOW – Low power mode (-65 to -20dBm) - external attenuator activated.
3=AUPC-LOW – AUPC enabled and external attenuator activated
Example: <0/AUP=1 (AUPC Enabled)
Notes:
1) EDMAC or D&I++, E1 D&I w/ccs or ESC++ framing must be selected for the AUPC feature to be available.
2) External 20dB Attenuator is a hardware option.
AUP=
AUP?
AUP*
AUP#
AUP?
AUP=x
(see Description of
Arguments)
AUPC
Parameters
APP=
6 bytes
Command or Query.
Sets or returns AUPC operating parameters in the form abc.cd, where:
a=Action on max. power condition: (0=do nothing, 1=generate Tx alarm)
b=Action on remote demod unlock: (0=go to nominal power, 1=go to max power)
c.c=Target Eb/No value, in dB, for remote demod from 0.0 thru 14.9:
Numbers above 9.9 use hex representation for the first character, i.e. 14.9 is coded as E.9.
d =Max increase in Tx Power permitted, in dB, from 0.0 thru 9.0
Example: <0/APP=015.67 (Sets no alarm, max power, 5.6 dB Target and 7 dB power increase.)
APP=
APP?
APP*
APP#
APP?
APP=abc.cd
(see Description of
Arguments)