8.5.6

Modem Information

Parameter

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Hardware

Revision

N/A

4 bytes

Query only.

Returns hardware revision level of both main circuit cards in the form xx.y, where:

xx indicates the main (bottom) card;

y indicates the top (modem) card.

N/A

HRV?

HRV=xx.y

(see Description of

Arguments)

Software

Revision

N/A

5 bytes

Query only.

Returns the installed firmware version number, in the form x.x.x, where:

Example: <0/SWR? >0/SWR=2.0.2

N/A

SWR?

SWR=x.x.x

(see description

of arguments)

Firmware

Information

N/A

256 bytes

Query only.

Returns the installed firmware information.

Note: <0/FRW?B requests boot code information.

Example: FRW=Boot: FW-0020732-,1.1.1,01/08/13

Otherwise, FRW returns firmware information for Image 1 or 2:

Example:

<0/FRW?

>0/FRW=1:FW-0020731E,1.3.1L,07/10/14

FW-0020733C,1.3.1L,07/10/14

FW/12867AG ,2.3.3,28/07/14

FW/12868L ,2.3.1,15/04/13

FW-0020735B,1.3.1,11/09/14

FW/12874C ,1.6.0,15/08/11

FW-0020734D ,1.3.1,07/10/14

FW-0020739-,1.1.1,24/07/13

FW-0000516-,1.1.1,19/01/11

FW-0020740v,1.1.v,06/08/14

N/A

FRW?B

FRW?1

FRW?2

FRW=xxx…xxx

(see Description of

Arguments)

Serial Number

N/A

9 bytes

Query only.

Returns the modem 9-digit serial number.

Example: <0/SNO? >0/SNO=176500143

N/A

SNO?

SNO=xxxxxxxxx

(see Description of

Arguments)

Fractional CnC

90-day Counter

N/A

7 bytes

Query Only.

Returns the number of seconds that Fractional CnC license has been used in the 1-year period since the last reset of the

CnC counter to 0.

Example: <0/FCC? >0/FCC=0000455 (indicating 455 seconds)

N/A

FCC?

FCC=xxxxxxx

(see Description of

Arguments)

Modem

Operational Full

Year Counter

N/A

8 bytes

Query Only.

Returns the number of seconds that the unit has been powered on since the last reset of the CnC counter.

The counter resets to 0 when it reaches 31536000 seconds (seconds in 365 days).

Example: <0/FCF? >0/FCF=00001342 (indicating 1342 seconds)

N/A

FCF?

FCF=xxxxxxxx

(see Description of

Arguments)

Software

Revision 2

N/A

38 bytes

Query only.

Returns the installed firmware version numbers in the Boot, Image 1, and Image 2 slots.

Example: <0/SW2? >0/SW2=Boot:2.1.1 Bulk1*:2.1.2 Bulk2 :2.1.1

The current active image is indicated with an asterisk.

N/A

SW2?

SW2=x

(see Description

of Arguments)