6.2.5 SELECT: Store/Ld (Store/Load) Menu Branch

Configuration #2: Load Store

()

AVAILABLE

You can store up to 10 modem configurations into an assigned “slot” – 0 through 9. If a

configuration slot is available for storage, the bottom line notes the status of that slot as

AVAILABLE. Otherwise, if the slot contains an existing configuration, the bottom line specifies its

storage time in military format (HH:MM:SS); the date displays DAY-MONTH-YEAR format in

accordance with European convention.

To load (recall) a configuration setting:

First, use the

◄ ►

arrow keys to move the cursor to the configuration slot number

(

Configuration #X

) and then use the

▲▼

arrow keys to select a slot number from 0 to

9.

Next, use the

◄ ►

arrow keys to select Load, and Press ENTER. Modem operation then

updates as per the configuration settings stored in this slot.

To store (save) a configuration setting:

First, make any desired configuration changes to the modem.

Next, use the

◄ ►

arrow keys to move the cursor to the configuration slot number

(

Configuration #X

) and then use the

▲▼

arrow keys to select a slot number from 0 to

9.

Finally, use the

◄ ►

arrow keys to select Store, and Press ENTER.

Once you store a modem configuration into the designated slot, the unit records the time and

date and this information appears on the bottom line.

Store Override – When storing into a configuration slot that previously had information saved

into the working memory, you must confirm the request as the unit will overwrite the existing

information:

Configuration #2. Override? No (Y,N) ()

14:06:37 26/10/14

Use the

▲▼

arrow keys to select the Override choice (Y or N). Press ENTER.