Comtech EF Data CDM-625A User Manual

Page 499

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

CDM-625A ODU (Transceiver, BUC, LNB) Operation

Revision 3

10–31

ODU: FSK-control BUC Advanced-FSK LPOD (2LPODs

Online/Offline LPOD) Statistics Config

Stats: Logging=Enabled Interval=10 min

Averaging=Disabled Clear-All=No (◄ ►)

Use the

▲▼

arrow keys to select Logging, Interval, Averaging, or Clear-All, and then use the

▲▼

arrow keys to set that setting:

Selection

Setting

Logging

Enabled or Disabled.

Interval

The Logging Interval is the period of time over which performance statistics are

measured. Set this interval as 00 to disable the feature (i.e., no logging) or,

otherwise, define the logging interval from 10 through 90 minutes in 10-minute

increments.

Averaging

Enabled or Disabled.

Clear-All

When prompted, select YES.

Press ENTER when done.

ODU: FSK-control BUC Advanced-FSK LPOD (2LPODs

Online/Offline LPOD) Statistics Stored-Statistics

To enable statistics logging, see the LPOD Statistics: Config menu. As statistics are compiled,

the Stored-Statistics screen appears as shown here:

Reading Stored Stats..... Please Wait

Once the statistics are compiled, the Stored-Statistics screen displays this data as shown here:

Stats001: 000.0C 040.0C 20.45dBm 10.00dB

10/01/10 12:52:08 On On Off 001.0 002.3V

Use the

▲▼

arrow keys to scroll backwards or forwards through the statistics log entries.

The top line displays:

• The statistics log entry number (up to 512 entries may be stored)

• Operating Temperature

• Amplifier Temperature

• Power

Advertising