12 config: remote (remote control), 1 config: remote ( local or serial remote settings – Comtech EF Data CDM-625A User Manual

Page 180

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Front Panel Operation

Revision 3

6–54

6.2.1.12 CONFIG: Remote (Remote Control)

Remote Control=Local

(Local,Serial remote,Ethernet)

()

Use the

▲▼

arrow keys to select Local, Serial remote, or Ethernet. Press ENTER.

When you select Local, you are not permitted to reconfigure the modem via Serial Remote or

Ethernet, although remote monitoring is permissible. When you select Local or Serial Remote,

the modem displays a common submenu – proceed to the next section for details.

6.2.1.12.1 CONFIG: Remote Local or Serial remote settings

Interface= RS-485-4W (232,485-2,485-4)

Address= 0001 9600 baud

()

When you select either Local or Serial remote control, use the

◄ ►

arrow keys to select

Interface, Address, or Baudrate. Then, use the

▲▼

arrow keys to edit the Interface type,

Baudrate, and each digit of the Address.

Note that:

• Character format is not selectable and is fixed at 8-N-1.

For RS-485 (aka EIA-485) – The permitted address range is from 0001 to 9999. Address 0000

is reserved for universal addressing.

For RS-232 (aka EIA-232) – The Address is fixed at 0000.