CDM-625A Advanced Satellite Modem

MN-CDM625A

Rear Panel Connectors and Pinouts

Revision 3

3–14

3.2.2.5 ESC (DB-9F)

The ESC (Engineering Service Channel) port is a 9-pin Type ‘D’ female

connector.

Table 3-9. ESC Connector Pinouts

(R>L)

Pin #

Asynchronous

Synchronous

5

––

EIA-232 Tx Clock Out

9

EIA-485 Rx Data A Out

––

4

––

EIA-232 Rx Clock Out

8

EIA-485 Rx Data B Out

––

3

EIA-232 Tx Data In

EIA-232 Tx Data In

7

EIA-485 Tx Data A In

––

2

EIA-232 Rx Data Out

EIA-232 Rx Data Out

6

EIA-485 Tx Data B In

––

1

Ground

Ground

3.2.3 Utility Connections Group

3.2.3.1 Remote Control (DB-9M)

The Remote Control interface is a 9-pin Type ‘D’ male connector. It is

intended for connection to an M&C computer or terminal device, and is user

selectable for either EIA-232 or EIA-485.

Table 3-10. Remote Control Connector Pinouts

(L>R)

Pin #

Description

Direction

1

Ground

––

6

EIA-485 Receive Data ‘B’ *

In

2

EIA-232 Transmit Data

Out

7

EIA-485 Receive Data ‘A’ *

In

3

EIA-232 Receive Data

In

8

EIA-485 Transmit Data ‘B’ *

Out

4

Reserved – Do Not Use

––

9

EIA-485 Transmit Data ‘A’ *

Out

5

Ground

––

*Use for EIA-485 2-wire operation

Advertising