8–30

Parameter

Command

(Instruction

& Qualifier)

Length of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Unit Alarm

Mask

MSK=

13 bytes

Exception –

600L Emulation:

6 bytes

Command or Query.

Sets or returns Alarm Mask conditions in form abcdefghjklxx, where:

a=Tx AIS

b=Rx AIS

c=bufferslip Alarm

d=spare

e=Rx AGC Alarm

f=Eb/No Alarm

g=BUC Alarm

h=LNB Alarm

j=G.703 Loss of Signal alarm

k=Reference alarm

l=Tx Clock Alarm

m=CnC Lock Alarm

x (spare)

Value of each mask:

0=unmasked

1=masked

Example: <0/MSK=0101100000000

MSK=

MSK?

MSK*

MSK#

MSK?

MSK=abcdefghjklxx

(see Description of

Arguments)

Attach summary

BUC fault to Tx

FLT status

ABA=

1 byte, 0 or 1

Command or Query.

Sets or returns BUC fault reporting in the form x, where:

0=Tx FLT status unaffected by BUC fault

1=Attach a summary BUC fault to Tx FLT status

ABA=

ABA?

ABA*

ABA#

ABA?

ABA=x

(see Description of

Arguments)

Attach summary

LNB fault to Rx

FLT status

ALA=

1 byte, 0 or 1

Command or Query.

Sets or returns LNB fault reporting in the form x, where:

0=Rx FLT status unaffected by LNB fault

1=Attach a summary LNB fault to Rx FLT status

ALA=

ALA?

ALA*

ALA#

ALA?

ALA=x

(see Description of

Arguments)

Number of

Unread stored

Events

N/A

3 bytes

Query only.

Returns the number of stored events that remain unread over remote control, in the form xxx, where xxx=000-255.

Example: <0/NUE? >0/NUE=126

N/A

NUE?

NUE=xxx

(see Description of

Arguments)

Retrieve next

five unread

Stored Events

N/A

80 bytes

Query only.

Returns the oldest five stored events that have not yet been read over remote control in the form

[CR]sub-body[CR]sub-body[CR]sub-body[CR]sub-body[CR]sub-body. Sub-body=ABCddmmyyhhmmss, where:

A=fault/clear indicator, where:

F=Fault

C=Clear

I=Info

B=fault type where:

1=Unit

2=Rx Traffic

3=Tx Traffic

4=Info (Power on/off, or log cleared)

5=Open Network

6=BUC

7=LNB

N/A

RNE?

RNE=[CR]ABCddmm

yyhhmmss[CR]ABCdd

mmyyhhmmss[CR]AB

Cddmmyyhhmmss[CR

]ABCddmmyyhhmmss

[CR]ABCddmmyyhhm

mss

(see Description of

Arguments)