8–35

Parameter

Command

(Instruction

& Qualifier)

Length of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

POCO

feature

(Power-On

Carrier-Off)

PCO=

1 byte, 0 or 1

Command or Query.

When enabled, when a modem is power cycled, it powers up with the Tx carrier setting OFF.

0=POCO disabled (normal operation)

1=POCO enabled – Use with caution!

Example: <0/PCO=0 (disabled – normal operation)

PCO=

PCO?

PCO*

PCO#

PCO?

PCO=x

(see Description of

Arguments)

DoubleTalk

Carrier-in-

Carrier (CnC)

Mode

CNM=

1 byte, 0 thru 9

Command or Query.

Sets or returns CnC operation in the form x, where:

0=Off

1=On (normal)

2=APC, C-Band, Side A

3=APC, X-Band, Side A

4=APC, Ku-Band, Side A

5=APC, Ka-Band, Side A

6=APC, C-Band, Side B

7=APC, X-Band, Side B

8=APC, Ku-Band, Side B

9=APC, Ka-Band, Side B

Notes:

1) CnC may be enabled only if:

The optional plug-in hardware CnC card has been installed AND a CnC FAST option is unlocked.

The range of permitted data rates is controlled by a FAST feature code. (Read EID to decode the installed

options for the modem)

2) If CnC-APC is active (APS=22), key transmission/reception (Modulation, FEC type, Code Rate, Framing, Data Rate,

Interface) cannot be modified until CnC-APC is suspended. (Use APC command to suspend or activate.)

CNM=

CNM?

CNM*

CNM#

CNM?

CNM=x

(see Description of

Arguments)

DoubleTalk

Carrier-in-

Carrier (CnC)

PMSI Mode

CPM=

1 byte, 0 thru 3

Command or Query. (CnC parameter)

Sets or returns CnC PMSI (Pre-Mapped-Symbol Interface) mode in the form x, where:

0=Idle

1=Redundancy (1:1 or 1:N)

2=Talk

3=Listen

CPM=

CPM?

CPM*

CPM#

CPM?

CPM=x

(see Description of

Arguments)

CnC

Frequency

Range/offset

CCF=

3 bytes

Command or Query. (CnC parameter)

Sets or returns the maximum value that may be entered, in the form xxx, as the CnC Sweep frequency range depends on

the Rx symbol rate as follows:

CCF=

CCF?

CCF*

CCF#

CCF?

CCF=xxx

(see Description of

Arguments)

18ksps to 64ksps:

64ksps to 389ksps:

389ksps to 2000ksps:

>2000ksp

±

1 to the symbol rate (ksps)/2

±

1 to 32 kHz

±

1 to 10% of sym rate

±

1 to 200 kHz

Example: <0/CCF=030

CnC

Min/Max

Search Delay

CSD=

6 bytes

Command or Query. (CnC parameter)

Sets or returns CnC min/max delay value in milliseconds, in the form xxxyyy, where:

xxx=minimum delay

yyy=maximum delay

Maximum allowable value is 330ms

Example: <0/CSD=010325

CSD=

CSD?

CSD*

CSD#

CSD?

CSD=xxxyyy

(see Description of

Arguments)