Read Only, Read/Write, Admin Names and Passwords – The factory defaults for these user

names and passwords are:

Description

Factory Default User Name / Password

Typical Parameters

Read Only

monitor / 1234

Name and Password fields can be any

alphanumeric combination with a

maximum length of 10 characters.

Read/Write

opcenter / 1234

Admin

comtech / comtech

SMTP Server – Specify the mail server IP Address from where e-mail may be sent.

SMTP Domain Name / Destination – The Administrator can assign the SMTP Domain Name

and Destination.

o SMTP Domain Name – Specify the domain of the e-mail server (usually found to the

right of the @ symbol in an e-mail address).

o SMTP Domain Destination – Specify the e-mail recipient name (usually found to the left

of the @ symbol in an e-mail address).

Host Access List

IP (#) / Mask – The Host Access List allows a user to define which remote clients can connect

when the Access List is Enabled. Each entry allows a user to specify an IP Address and a

subnet mask to define a unique class of machines that are allowed access.

For example, if a user wanted to grant access to a PC with an IP Address of 10.10.10.1 and

any PC on a subnet of 192.168.10.XXX, and then the Access List would be defined as:

IP 1 / Mask – 10.10.10.1/32

IP 2 / Mask – 192.168.10.0/24

The check box before the IP (#) / Mask must be checked in order for that list entry

to take effect.

Access List – The Access List allows a user to grant access via HTTP and SNMP to a defined

list of client machines.

Use the drop-down to select Enable or Disable. If Disable is selected, then any client

machine will be able to connect via HTTP and SNMP.

Click [Submit Admin] to save.

RADIUS (Remote Authentication Dial In User Service)