Comtech EF Data CDM-625A User Manual

Page 59

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Introduction

Revision 3

1–15

Output impedance

950-1950 MHz band: 50Ω, 19 dB minimum return loss (21 dB typical)

1950-2250 MHz band: 17dB minimum

50-180 MHz band: 50Ω, or 75Ω 16 dB minimum return loss (18 dB typical)

Output connector

950-2250 MHz band: Type N female

50-180 MHz band: BNC female

Clocking options

Internal, ±0.06 ppm (SCT)

External, locking over a ±100 ppm range (TT)

Loop timing (Rx satellite clock) - supports asymmetric operation - Rx and Tx data rates need not be identical

External Clock

G.703 Clock Extension mode – internal ST clock can be slaved to an external T1 or E1 G.703 signal, and a G.703

timing signal re-constituted at the distant end of the link, regardless of the actual link data rate

External TX Carrier Off

By TTL 'low' signal or external contact closure - hardware function automatically over-rides processor

BUC Reference (10 MHz):

Phase Noise

On center conductor of L-Band output connector; 10.0 MHz ± 0.06 ppm (internal reference selected)

0.0 dBm, ± 3 dB; programmable ON/OFF

Source: either Internal Modem Reference or External Reference (10 MHz)
dB/Hz

Frequency Offset

-105

10 Hz

-125

100 Hz

-138

1 kHz

-148

10 kHz

-150

100 kHz

BUC Supply Voltage

Standard unit has no BUC supply.

Optional BUC Supply:

o

24VDC, 4.17 Amps maximum, 100W

o

48VDC, 3.125 Amps maximum, 150W @ 50° C (180 watts @ 30° C)

o

Supplied through Tx IF center conductor and selectable ON/OFF via M&C control.

BUC Current Monitor

Min/Max programmable current alarm thresholds.

Tx Carrier ON Delay

Selectable feature power on to allow internal ovenized reference to stabilize before turning on Tx carrier. Intelligent

algorithm minimizes delay time based on internal temperature at power-up.

BUC Monitoring

Power level, temperature, power class, PLL lock.

Uses ND Satcom/Global VSAT Forum specification for FSK control and monitoring.