Comtech EF Data CDM-625A User Manual

Page 145

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Front Panel Operation

Revision 3

6–19

Encoder Type

Modulation Type

FEC Rate Choice

VF2L

(VersaFEC-2 Long Block)

or

VF2S

(VersaFEC-2 Short Block)

BPSK

Fixed at 0.489

QPSK

0.489, 0.537, 0.586, 0.611, 0.635,

0.660, 0.684, 0.733

8-ARY

0.521, 0.537, 0.562, 0.586, 0.611,

0.635, 0.770, 0.684, 0.708, 0.733

16-ARY

0.586, 0.611, 0.635, 0.660, 0.684,

0.708, 0.733, 0.757, 0.782

32-ARY

0.660, 0.684, 0.708, 0.733, 0.757,

0.782, 0.801, 0.831, 0.855, 0.879

When the TPC/LDPC hardware option is installed and you select TPC from the CONFIG: Tx >FEC

submenu, the options appear as shown:

Mod=QPSK (B,Q OQ,8PSK,16Q,8QAM)

FEC Rate=1/2 (1/2,3/4,7/8,0.95) ()

When you select VFEC from the CONFIG: Tx > FEC submenu, the options appear as shown:

Mod=BPSK (B,Q,8QAM,16QAM) ()

FEC Rate=0.488 (Fixed)

When you select ULL from the CONFIG: Tx > FEC submenu, the options appear as shown:

Mod=BPSK (B,Q) ()

FEC Rate=0.493 (Fixed)

When you select VF2S or VF2L from the CONFIG: Tx > FEC submenu, the options appear as

shown:

Mod=BPSK (B,Q,8/16/32-ARY) ()

FEC Rate=0.489 (Fixed)