Comtech EF Data CDM-625A User Manual

Page 326

Advertising
background image

CDM-625A Advanced Satellite Modem

MN-CDM625A

Serial-based Remote Product Management

Revision 3

8–14

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Tx Sub-Mux

Ratio

TMR=

2 bytes, numeric Command or Query.

Sets or returns Tx Sub-Mux Ratio (IP/Synchronous Interface) in the form xx, where

TMR?

TMR=

TMR*

TMR#

TMR?

TMR=xx

(see Description of

Arguments)

00=1/9

01=1/8

02=1/7

03=1/6

04=1/5

05=1/4

06=2/7

07=1/3

08=2/5

09=3/7

10=1/2

11=3/5

12=2/3

13=3/4

14=4/5

15=1/1

16=5/4

17=4/3

18=3/2

19=5/3

20=2/1

21=7/3

22=5/2

23=3/1

24=7/2

25=4/1

26=5/1

27=6/1

28=7/1

29=8/1

30=9/1

31=1/59

32=1/39

33=1/19

Example: <0/TMR=01 (Selects ratio 1/8)

Tx

Reed-Solomon

Encoding

TRS=

1 byte, 0 thru 3

Command or Query.

Sets or returns Tx RS encoding in the form x, where:

0=Normal (based on the Open Network framing selected)

1=IESS-310 mode, valid with QDI, unframed, IBS, D&I, IDR.

2=EF Data legacy standard (225,205) – unframed, QDI only

3=IBS (126,112) – unframed only

Example: <0/TRS=0 (This is a ‘don’t care’ if no RS is selected under FEC Type)

Available all framing modes, except EDMAC.

TRS=

TRS?

TRS*

TRS#

TRS?

TRS=x

(see Description of

Arguments)

Tx Spectrum

Invert

TSI=

1 byte, 0 or 1

Command or Query.

Sets or returns Tx Spectrum Invert selection in the form x, where:

0=Normal

1=Tx Spectrum Inverted

Example:TSI=0 (selects normal)

TSI=

TSI?

TSI*

TSI#

TSI?

TSI=x

(see Description of

Arguments)

Tx Scrambler

TSC=

1 byte, 0 thru 2

Command or Query.

Sets or returns Tx Scrambler State in the form x, where:

0=Off

1=Normal

2=IESS-315

Note: When CnC mode is ON, Tx Scrambler state is fixed as IESS-315.

Example: <0/TSC=1 (Scrambler On)

TSC=

TSC?

TSC*

TSC#

TSC?

TSC=x

(see Description of

Arguments)

Tx Power Level TPL=

4 bytes

Command or Query.

Sets or returns Tx Output power level in the form xx.x, where:

Level=Value from 00 thru -40 dBm (minus sign assumed) for 950 or 1950MHz range.

Level=Value from 00 thru -25 dBm (minus sign assumed) for 50 or 180MHz range.

Example: <0/TPL=13.4

Note: In AUPC mode, command is not valid. Response will be TPL*.

When APC is active, query returns “TPL=99.9”; when command is not valid, response will be TPL*.

When the external 20 dB attenuator is activated (via AUP), the permitted power level range shifted down by 20dB.

Example: -65 and -20 dBm.

600 Emulation: Level range is from 00 thru -20 dBm (minus sign assumed).

600L Emulation: Level range is from 00 thru -45 dBm (minus sign assumed).

TPL=

TPL?

TPL*

TPL#

TPL?

TPL=xx.x

(see Description of

Arguments)

Advertising